E&J Geothermal knows how much of an investment a new heating, air conditioning, air quality or geothermal system can be. That's why we want to help you protect your investment!
Geothermal |
Furnace |
Air Conditioner |
Gas Fireplace |
Generator |
---|---|---|---|---|
Inspect air coil & fan housing | Remove and clean burners | Clean condenser coil | Remove and clean glass | Verify proper gas pressures |
Check loop water, heat exchanger, and hot water generator | Remove, test, and clean flame sensor | Check electrical components | Check blower for proper operation | Change oil (Oil not included) |
Check condensate drain and pipe drain | Brush heat exchanger and check for cracks/holes | Check and record amp draw on compressor | Vacuum out fireplace and logs | Change air filter (Filter not included) |
Add condensate drain pain treatment | Measure CO reading in flue and plenum | Check and record amp draw on blower motor | Re-spray inside of enclosure with flat black paint | Change oil filter (Filter not included) |
Check back-up heat | Clean and flush condensate drain | Clean condensate trap and pump (if applicable) | Replace logs and redress embers | Verify proper operation of transfer switch |
Check control panels | Inspect evaporator coil | Visual leak inspection on evaporator coil and condenser coil | Check for proper venting operations | Record all reading and hour usage |
Check contactors, capacitors and relays | Test amp draw on blower motor | Verify refrigeration charges (Refrigerant not included) | Check electrical components for proper operations | Check electrical components for proper operations |
Check compressor electrical draws | Inspect electrical components | Add condensate drain pan treatment | ||
Check and clean filter | Replace air filters (Filters not included) | |||
Yearly | Yearly | Yearly | Every 2 Years | Yearly |
Geothermal |
Furnace |
Air Conditioner |
||
---|---|---|---|---|
Inspect air coil & fan housing | Remove and clean burners | Clean condenser coil | ||
Check loop water, heat exchanger, and hot water generator | Remove, test, and clean flame sensor | Check electrical components | ||
Check condensate drain and pipe drain | Brush heat exchanger and check for cracks/holes | Check and record amp draw on compressor | ||
Add condensate drain pain treatment | Measure CO reading in flue and plenum | Check and record amp draw on blower motor | ||
Check back-up heat | Clean and flush condensate drain | Clean condensate trap and pump (if applicable) | ||
Check control panels | Inspect evaporator coil | Visual leak inspection on evaporator coil and condenser coil | ||
Check contactors, capacitors and relays | Test amp draw on blower motor | Verify refrigeration charges (Refrigerant not included) | ||
Check compressor electrical draws | Inspect electrical components | Add condensate drain pan treatment | ||
Check and clean filter | Replace air filters (Filters not included) | |||
Yearly | Yearly | Yearly |
Gas Fireplace |
Generator |
Remove and clean glass | Verify proper gas pressures |
---|---|
Check blower for proper operation | Change oil (Oil not included) |
Vacuum out fireplace and logs | Change air filter (Filter not included) |
Re-spray inside of enclosure with flat black paint | Change oil filter (Filter not included) |
Replace logs and redress embers | Verify proper operation of transfer switch |
Check for proper venting operations | Record all reading and hour usage |
Check electrical components for proper operations | Check electrical components for proper operations |
Every 2 Years | Yearly |